CHAPTER 9. BUILDINGS.*
Sec. 9-55.4. Standards for manufactured homes.
(a) All new and replacement manufactured homes and additions
to manufactured homes that are placed or substantially improved within Zones
A1-30, AH, and AE on the community's Flood Insurance Rate Map, on sites
located:
(1) Outside of a manufactured home park or
subdivision,
(2) In a new manufactured home park or subdivision,
(3) In an expansion to an existing manufactured home park or
subdivision, or
(4) In an existing manufactured home park or subdivision on a
site upon which a manufactured home has incurred "substantial damage" as the
result of a flood,
shall be elevated on a permanent foundation such that the
lowest floor of the manufactured home is elevated two feet (minimum) above the
base flood elevation and be securely fastened to an adequately anchored
foundation system to resist flotation, collapse, and lateral movement.
(b) All manufactured homes to be placed or substantially
improved on sites in an existing manufactured home park or subdivision within
Zones A1-30, AH, and AE on the community's Flood Insurance Rate Map that are not
subject to the provisions of subsection (a) of this section will be securely
fastened to an adequately anchored foundation system to resist flotation,
collapse, and lateral movement, and be elevated so that either:
(1) The lowest floor of the manufactured home is elevated two
feet (minimum) above the base flood elevation, or
(2) The manufactured home chassis is supported by reinforced
piers or other foundation elements of at least equivalent strength that are no
less than thirty-six inches in height above grade.
Upon the completion of the structure, the elevation of the
lowest floor including basement shall be certified by a registered professional
engineer or surveyor, and verified by the community building inspector to be
properly elevated. Such certification and verification shall be provided to the
floodplain administrator. (Ord. No. 1835 (NCS), § 1; Ord. No. 2037, §
11; Ord. No. 2383 (NCS), § 1.)